<LOGO>
FM Transmitter Measurement Report
Created: 2025-09-18 08-42-18
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
103.10 MHz 5/5, 65 dBuV RMC
Pilot RDS Phase Difference
0.0 kHz 3.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
4 kHz 74 kHz 9051 0,2431
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
8,2 dBr 8,32 dBr 8,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RMC " F216 0 (No PTY) 1 0 1 1 8:42, 18.09.2025
RT
-
AF EON
87.6, 87.7, 90.2, 90.4, 90.6, 92.3, 95.3, 96.4, 97.3, 99.1, 100.7, 101.2, 101.6, 102.6, 103.1, 103.2, 103.3, 103.6, 104.1, 104.8, 106.7, 107.2, 107.3, 107.5, 107.9 MHz -
FM Scope Station: 103.10 MHz, signal: 5/5 (64 dBuV) Max at: 74 kHz MIN: 4 kHz % above 75 kHz: 0,2431 Acquired: 2025/09/18 8:41:14 Total samples: 9051 Equivalent time: 0:07:32 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 8,5 dBr MIN: 8,2 dBr AVE: 8,32 dBr % above 10,2 dBr: 0,0 Last value: 8,3 dBr (2025/09/18 8:41:14) Station: 103.10 MHz, signal: 5/5 (64 dBuV) 08:34 08:35 08:36 08:37 08:38 08:39 08:40 08:41 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality